目的
建立HPLC测定溴化丁基橡胶垫片中硫单质的方法,并对其向清心安神口服液迁移进行研究。
方法
采用Dikma Diamonsil C
18
色谱柱(250 mm×4.6 mm,5 μm);检测波长为272 nm;流动相为乙腈-四氢呋喃-水(60∶30∶10);柱温为30℃;流速为1.0 mL·min
–1
。
结果
硫单质在0.023~233.228 μg·mL
–1
内线性关系良好(
r
=0.999 9),定量限为0.023 32 μg·mL
–1
,检出限为0.005 831 μg·mL
–1
,加样回收率为93.4%,迁移回收率为95.6%。
结论
方法简便快速、准确可靠、重复性好,可用于溴化丁基橡胶垫片中硫单质的测定,为国家药典增订硫单质的测定提供实验基础。
关键词
:
溴化丁基橡胶垫片
硫单质
高效液相色谱法
迁移研究
DOI:
10.13748/j.cnki.issn1007-7693.2021.22.012
分类号
:
R927.11
OBJECTIVE
To establish a method for the determination of sulfur in brominated butyl rubber gasket and its migrating research to Qingxin'anshen oral liquid by HPLC.
METHODS
The Dikma Diamonsil C
18
column(250 mm×4.6 mm, 5 μm) was used with the mobile phase of acetonitrile-tetrahydrofuran-water(60:30:10). The wavelength was 272 nm. The column temperature was 30℃. The flow rate was 1.0 mL·min
-1
.
RESULTS
The calibration curve of sulfur was linear over the range of 0.023-233.228 μg·mL
-1
(
r
=0.999 9). The limit of quantification was 0.023 32 μg·mL
-1
. The detection limit was 0.005 831 μg·mL
-1
. The sample recovery rate was 93.4%, and the migration recovery rate was 95.6%.
CONCLUSION
The method is simple, rapid, accurate, reliable and reproducible. It can be used for the determination of elemental sulfur in brominated butyl rubber gaskets, and provides an experimental basis for the determination of elemental sulfur in the national pharmacopoeia.
Key words
:
brominated butyl rubber gasket
elemental sulfur
HPLC
migration research
地址:杭州市滨江区平乐街325号浙江省食品药品检验研究院2楼212室